Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.8782492
![](http://i.b2b168.com/e/tag_cmjz.gif)
- Product Categories
- LED Explosion-proof lamp se..
- LED Industrial Lighting Ser..
- LED street lamp series
- Discharge lamp series
- Industrial Lighting Series
- Plant Explosion lamp series
- Mobile lighting series
- Fixed explosion-proof light..
- Explosion-proof electrical ..
- Anti-corrosion electrical s..
- Friendly Links
- Packaging, Paper companies
- Packaging, Paper products
- Packaging, Paper buy leads
- My business card
- China Business News
- My mobile shop
- Explosion-proof electri..
- Explosion-proof non-pol..
- Explosion-proof energy-..
- Explosion-proof fluores..
- LED High Bay
- LED mining lamp
- LED explosion proof lig..
- LED street lights
- Mobile lighting
- Industrial lighting
- Fixed lighting
- Honesty
- Quality first
- Low-carbon energy
- Honesty
- Efficient and environme..
- Histon electrical
- Yixing Vantage Electric..
Information Name: | Supply 160WLED explosion proof LED street lights (BAD808-L) |
Published: | 2015-07-09 |
Validity: | 30 |
Specifications: | BAD808-L |
Quantity: | |
Price Description: | |
Detailed Product Description: | LED explosion proof lights (BAD808-L) 70w 80w 100w 120w 160WLED proof lights Explosion-proof lights _LED road LED light LED road lights Explosion-proof lights 100W high power led explosion proof lights 100W LED lights First, the use of environmental conditions: 1, altitude: ≤1000M; 2, ambient temperature: -20 ℃ ~ 50 ℃; 3, the design wind speed: 36.9m / s; 4, relative humidity: 80%; 5, seismic intensity: 8 Second, the use of standards: all the equipment and materials all aspects of manufacturing, laboratory, etc. should follow the following criteria: GB7000.1-9 "general safety requirements and test fixtures" GB7001 "protective shell lamps CLASSIFICATION" GB7003 "lighting electroplating, chemical overlay" GB7248 "electric light safety requirements" GB9468 " road lighting photometric test "GB11470" electric light source product quality grading and other indicators "GB5702" light color comment method "GB50259" city road lighting project construction and acceptance "CJJ89-2001" city road lighting project construction and acceptance "IEC60598 "international safety standards" three, interchangeable: the same type of lighting and accessory structures, performance parameters, size, etc., should be identical sample lighting materials and performance of all original spare parts should be provided with the same device. 4, test: After the device is installed to conduct field tests, the supplier shall send people to participate, all test results should meet GB50259 "works of electrical installations Electrical lighting equipment for construction and acceptance of" the relevant requirements. Five poles technical requirements, in line with the current national regulations streetlight acceptance criteria. 2, the poles lighting parameters, size, appearance see drawing 3, the inner and outer surfaces of the poles using galvanized embalmed after spray, the color renderings prevail, smooth surface, no color, no pinholes, no sagging, No peeling and so on; galvanized thickness not less than 85 microns, spray thickness not less than 100 microns. 4, rod, high-quality carbon steel rungs, no obvious signs of dents and the like, and the main bar as hot-dip galvanized, spray. 5, the flange plate cut to shape, the surrounding smooth, no glitches, beautiful appearance, accurate holes. 6, the appliance door using plasma cutting, accurate size, smooth surface, and anti-theft devices and grounding welding equipment. 7, Tongxin terminals quality reach the national electrical industry standards. 8, street design wind speed greater than 35 m / sec, earthquake greater than 8 to ensure that the whole street lamps work in bad weather conditions. Six shell lamps and reflectors Technical requirements: A, technical requirements: 1, lamp kit of parts by the impact of pressure cast aluminum components. 2, high purity aluminum oxide reflector, specially designed by computer, linear and smooth, full curve uniform, high light efficiency. 3, high-strength glass temperature arc, with a flexible silicone seal, seal rating of IP65. 4, the lid open manner, with safety stainless steel buckle. 5, electrostatic spray surface treatment, anti-ultraviolet radiation, color according to renderings. 6, the lamp used fasteners made of stainless steel. 7, lamps with integrated design, electrical cavity and light source cavity split. 8, high-purity aluminum reflector stretch forming, polishing treatment after anodizing, the reflectivity requirements ≥80%, and does not oxidize within a decade. 9, the transparent part of good transparency, high strength, high temperature, anti-glare glass reinforced water. B, basic properties: 1, protective performance: IP65 2, shell protection performance: Level Ⅱ 3, the working environment: -35 ℃ ~ + 45 ℃ 4, electric shock protection class: Class Ⅰ seven, electrical system technical requirements: the distribution source, Appliances must be for the same brand and the same trademark for products and meet the matching requirements. The ballast used to be full of copper wire through TW130 tested and should be consistent with national energy efficiency limit requirements. And equipped with the insurance compensation capacitor (single phase MCB) and other unified installation in the luminaire (lamp can be installed during construction) connected circuit, the wiring should be correctly and firmly. Nine, the overall requirements: 1. Overall reasonable structure, waterproof IP65, waterproof lamps fully guaranteed, to ensure reliable operation and service life of the lamp. Technical parameters: Explosion Proof Exd II B T6 Gb rated voltage 220VAC 50Hz rated power 50W 60W 80W LED light source type of protection IP65 Corrosion grade WF2 Dimensions 446 × 166 × 306mm wall installation ceiling manner (b) (x) Embedded range (m) applies (q) lights type 1 and Zone 2 IIA, IIB class T1 ~ T6 group explosive atmosphere, as factories or places lighting purposes. Explosion-proof lights under the following conditions can be reliably work altitude does not exceed 2000m; ambient operating temperature is -20 ~ + 40 ℃; ambient air relative humidity less than 98% (when the temperature is + 25 ℃); suitable for 1 and Zone 2 Class II T1 ~ T6 group explosive atmosphere; in no damage to the metal and insulating properties of gases and vapors place; in the absence of a significant shake and shock vibration place; Pollution degree 3; Installation category II class. Structural characteristics of product performance standards: GB3836.1 ~ 2-2010, Q / HH 001-2011. This product is aluminum alloy, after the high-speed shot blasting surface electrostatic spray, waterproof, dustproof, anti-corrosion and other functions. Stainless steel exposed fasteners, transparent parts are made of tempered glass against high-energy shock, lamp explosion of joints structure mouth only, but the light source chamber and the connecting chamber, drive chamber separated, easy installation and maintenance, and reliable electrical performance; high quality aluminum reflector cover, improve the efficiency of the lamp. The lighting inside and outside the shell has a ground screw, the user uses the product should be grounded. |
Admin>>>
You are the 980441 visitor
Copyright © GuangDong ICP No. 10089450, Yixing Hua Hong Electronics Manufacturing Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility